Air conditioning in the attic: turn your attic into a pleasant space
Because of the heat in summer and the cold in winter, an attic often goes underused. Plenty of attics end up as storage, while there is a lot of extra living space to be had. With an air conditioner you turn a hot or cold attic into a comfortable room. Would you like HR Installatietechniek to install an air conditioner in your attic? We are happy to advise you on a solution that fits.
Request a quote
A no-obligation quote in 3 steps.
- A-brand equipment
- Reply within 48 hours
- Expert installation included
What you need to know about air conditioning in the attic
An air conditioner in the attic calls for a different approach than in the rest of the house. Extra heat comes in through the roof and any roof windows, so an attic usually needs more capacity than a room on a lower floor. The type of roof plays a part too: under a sloping roof there is less straight wall for an indoor unit than under a flat roof or in a dormer. That is why we always look at your attic and at how you use it.
Sloping roof
Flat roof or dormer
The different air conditioner models
Floor-standing models
Design models
Sleeping, working and living comfortably in the attic
Do you have several rooms in the attic? With an open layout, one indoor unit can sometimes partly reach several areas. If the rooms are closed off, each room needs its own indoor unit. With a multi-split system you connect several indoor units to one outdoor unit. That way you set the temperature you want room by room, and you only have one outdoor unit on the facade or the roof.
Where do you position the outdoor unit?
How many kW of air conditioning do I need for my attic?
Insulation level | Multiply by | Example room 4x4x2.5 m | Result (watts) | Capacity (kW) |
|---|---|---|---|---|
Well insulated | 30 watts/m³ | 40 m³ | 1,500 watts | 1.5 kW |
Averagely insulated | 40 watts/m³ | 40 m³ | 2,000 watts | 2.0 kW |
Poorly insulated / lots of glass | 50 watts/m³ | 40 m³ | 2,500 watts | 2.5 kW |
Attic floor area | Indicative capacity |
|---|---|
15 m² | +/- 1.9 kW |
20 m² | +/- 2.5 kW |
25 m² | +/- 3.1 kW |
30 m² | +/- 3.8 kW |
40 m² | +/- 5.0 kW |
In practice you choose the next standard capacity up from the calculation. For an exact calculation you can use our kW tool or call in HR Installatietechniek for a survey.
Work out how many kW of air conditioning you need
- Volume
- – m³
In an attic with a sloping roof, the roof surface determines the heat load, not the volume. We therefore calculate with the floor area × 2.5 m standard height, plus a 25% surcharge.
Our advice: choose an air conditioner with a capacity of – kW.
Are you using the air conditioner as your main heating? Then do not look at the nominal heating capacity alone, because that is measured at an outdoor temperature of +7 °C. In frost an air conditioner delivers less. Under ‘heating’, the energy label gives the design capacity for −10 °C (Pdesignh). Choose a model where that value is at least as high as the calculated heat demand.
This capacity is too high for a single air conditioner. Go for a multi-split system or ask us for advice.
This is an indicative calculation. Ventilation, the number of people, appliances and the outdoor temperature can all affect the capacity you need. Get in touch with us for an exact calculation.